Re: Response bogging down over time



******    message to minivend-users from Dan Busarow <dan@dpcsys.com>     ******

On Thu, 18 Mar 1999, Michael E. Havlicek wrote:
> To the point.... the disturbing thing that I found was that hacking the
> simple catalog base demo using defaults lead to a minivend who's performance 
> went to a grinding halt after 2 days.
> 
> I saw that there was an internal httpd that was discouraged. Perhaps I
> am using that? 
> 
> Restarting the minivend daemon sped things up.
> 
> So do I have to restart the minivend daemon daily or less to keep performance
> reasonable?
> 
> I found the instructions during installation very confusing regarding 
> the internal httpd (in installation it talked about an htttpd...:)

There is no need to restart minivend on any periodic basis.

The internal httpd is only used when talking to the MV socket interface
directly (INET domain socket).  You can use UNIX domain sockets or disable 
access to the internal server.  The internal server docs mention SCRIPT_PATH
and TcpMap.

Dan
-- 
 Dan Busarow                                                  949 443 4172
 Dana Point Communications, Inc.                            dan@dpcsys.com
 Dana Point, California  83 09 EF 59 E0 11 89 B4   8D 09 DB FD E1 DD 0C 82

-
To unsubscribe from the list, DO NOT REPLY to this message.  Instead, send
email with 'UNSUBSCRIBE minivend-users' in the body to Majordomo@minivend.com.
Archive of past messages: http://www.minivend.com/minivend/minivend-list